Mitel SX-50
Integrated Communications System uses an
innovative, compact modular design, which allows easy system expansion,
faultfinding and card replacement. Mitel's SX-50 is a digital electronic system,
using stored program control and advanced digital architecture. With a wide
range of features, the SX-50 is a favorite within the hotel industry with its
enhanced hospitality software.

- 160 Port Working
- SX50 can support full 160 port working.
- Up to a maximum of 32 Exchange Lines or 160
extensions.
- The 225W Power Supply Unit MUST be
installed on systems with more than 80 extensions.
SYSTEM CAPACITY: SX50 can
accommodate up to 10 Peripheral Cards. These cards can work in almost any
combination, so that the required customer con figuration can be achieved.
There are several circuit card limits which MUST NOT be exceeded. Depending on
the Power Supply Unit fitted, these maxima are:
-
With the 140W Power Supply
Unit, 24 Exchange Lines, 8 Private Circuits, 80 extensions, (or 32 SUPERSET
4s and 16 extensions).
-
With the 225W Power Supply
Unit, 32 Exchange Lines, 24 Private Circuits, 160 extensions, 32 SUPERSETS.
The installer can configure the SX50 in any way he chooses but MUST NOT
exceed the circuit card limits. The choice of circuit cards MUST be made
carefully, so that there are no more than 10 cards and that the limits are
not exceeded.
Circuit Cards - Up to 10 Peripheral Cards
can be installed, but the following numbers of individual circuit cards must not
be exceeded when using the 140W Power Supply Unit, NOT MORE THAN:
- (5) ONS (Extension) Cards
- (4) COV (SUPERSET) Cards
- (3) (8 circuit) Trunk Cards
- (6) (4circuit) Trunk Cards
- (4) Universal Cards
- (1) Digital Network Card, (NOTE: This card
uses two card slots)
- (8) SSDC5 and SSAC1SA modules
- (1) Music on Hold/Pager/MF4 module.
- (1) RMATS module can be installed.
Control Card - The Control Card MK3 is
situated at the back of the Card frame, parallel to the wall, and plugs directly
into the Power Supply Unit. The Control Card carries:
- Connectors for up to ten Peripheral Cards.
- The Central Processing Unit.
- Digital cross point switches.
- Call processing circuits.
- Timing and synchronisation circuits.
- MF4 circuits.
- Music on Hold/Paging circuits.
- Music on Hold/Paging Terminal Strip.
- Console jack.
- RS-232 port.
- A seven segment LED display.
- Four Status switches.
- One Reset switch.
- Night Bell Terminal Strip.
- Voltage Test Points.
Compatibility:
Peripheral Cards - Five types of
Peripheral Card (Extension, SUPERSET, Trunk, Digital Network Card and Universal
Card) are used in SX50. These are available in the following versions:
- Universal Card
- 16 circuit ONS (Extension) Card
- 8 circuit ONS (Extension) Card
- 8 circuit COV (SUPERSET) Card
- 8 circuit Trunk Card with 50 Hz Meter Pulse
Detectors
- 4 circuit Trunk Card with 50 Hz Meter Pulse
Detectors
- Digital Network Card
The Universal Card - is designed for a
variety of peripheral functions and is configured by attaching removable
modules. Up to four single-sized modules or two double-sized modules can be
plugged in to each Universal Card. The modules use two connectors per single
module or three connectors per double module. A group of four red LEDs on the
front of the Universal Card indicate the status of the modules and a single
green LED indicates the status of the card. There is a connector at the front
for the cable to the Test Jack Frame. Three types of plug-in module are
available for different configurations of the Universal Card. These are:
- SSAC15A Module. This is a single sized
module. Each module provides the circuits for. one SSAC1S Private Circuit
- SSDC5 Module. This is a double sized module
carrying the circuits for one SSDC5 E&M Private Circuit.
- RMATS Module. This single sized module
allows data entry and fault location to be carried out from a remote
Maintenance Centre.
**Note: We sell
CARDS, PHONES, and PARTS for your existing Mitel PBX - We do NOT sell complete
Mitel systems.